Egypt · 2024

SWRO pre-treatment media supply, Red Sea coast

Dual-media pre-treatment filters for a seawater reverse osmosis train, specified to hold SDI₁₅ below 3 at the membrane inlet.

Plant capacity
30,000 m³/day
Media supplied
310 t
Target SDI₁₅
< 3
Acid solubility
≤ 1.2%
  1. The problem

    Membrane fouling on a seawater train is expensive and slow to reverse, so the consultant specified a tighter acid solubility limit than the standard grade. Media that dissolves in service shifts the gradation and lets fines reach the membranes.

  2. What we supplied

    Dual-media beds of 0.8–1.6 mm anthracite over 0.8–1.6 mm silica sand, with acid solubility verified per lot against the tighter limit rather than the EN 12904 ceiling. Certificates were issued per layer for the submittal pack.

  3. Result

    Pre-treatment held SDI₁₅ within specification through commissioning and the first operating season.

Naming a client asserts both a commercial relationship and permission to publicise it. These profiles describe the duty, scale and outcome accurately; named references are available on request, with the client's consent.

Want to speak to a customer who has done this?

We will ask a client with a comparable duty whether they are willing to take your call. Some are; we never give out contacts without asking first.

Chat on WhatsApp