Applications

Desalination Plants

Pre-treatment filtration protecting SWRO membranes from suspended solids and biofouling.

Specifying note

SDI₁₅ below 3 is the target leaving pre-treatment. Low acid solubility matters here — media that dissolves shifts the gradation and lets fines reach the membranes.

Design parameters

Filtration rate
10 – 20 m/h
Target SDI₁₅
< 3
Acid solubility limit
≤ 1.5%

Typical bed configuration

  • Layer
    Coarse layer
    Media
    Filter anthracite
    Gradation
    0.8 – 1.6 mm
    Depth
    500 mm
  • Layer
    Filtration layer
    Media
    Silica filter sand
    Gradation
    0.8 – 1.6 mm
    Depth
    400 mm
  • Layer
    Support layers
    Media
    Support gravel
    Gradation
    2 – 32 mm
    Depth
    450 mm

A starting point, not a design. Final layer depths follow from vessel diameter, design filtration rate and target effluent quality.

Need this grade?

Send the gradation, the volume and the destination port. Our technical team responds within one working day with pricing, lead time and a specimen certificate of analysis.